Bid Requests
Infrastructure for Lupine Flats
Moscow Affordable Housing Trust is seeking bids to construct underground utilities and a retaining wall for a small development on E. Palouse River Drive at Nursery St in SE Moscow.
Bids are due 5PM July___ by email to Director@MoscowHousingTrust.org
or delivered to the office at 501 W Palouse River Dr. Moscow, ID 83843
Contact
Nils Peterson, Exec. Director
Director@MoscowHousingTrust.org
509/336-1664 cell
Site Location
The site is in SE Moscow, ID, near the intersection of E. Palouse River Dr. and Nursery St.
The project has 2 components, you may bid on either one or both. MAHT reserves the right to choose the most suitable bids based on cost, timing to start and proposed retaining wall materials.
Use your own bidding format. Bids should clearly state (if being bid)
Cost for
a. Component 1: Underground Utilities and/or
b. Component 2: Retaining wall
Earliest estimated start date
Proposed material for retaining wall
Email address for communication
COMPONENTS (see diagram below)
Underground utilities.
a. Tap water main in E. Palouse River Drive and bring water to 6 meters in a water meter vault in the tree lawn on the north side of Palouse River Drive
b. Bring water from the meters north up the hill and distribute lines to 6 house sites
i. Bring one line to a house under construction (442 E Palouse River Dr)
ii. Stub 4 lines into the general area of the future foundations
iii. Install a frost free hydrant on the 6th line (412 E Palouse River Dr)
c. Bring other utilities to house under construction (442 E Palouse River Dr)
i. Extend de-energized Avista conduit to new location for Avista pedestal
ii. Extend Sanitary and Storm sewers from existing stubs to house under construction
iii. Bring conduit for cable & phone from current stubs to house under construction
d. Bring other utilities to future house site (330 E Palouse River Dr)
i. Extend Sanitary and Storm sewers from existing stubs to vicinity of foundation
ii. Extend de-energized Avista conduit to new location for Avista pedestal
iii. Bring conduit for cable & phone from current stubs to new pedestal location adjacent to Avista
(Note: Utility service will not be extended to 412, 418, 424, and 436 in this project)
Retaining Wall
a. Construct a 4 foot tall retaining wall for approximately 150 feet along the southern property boundary of 6 lots. (Boulder preferred, other materials possible)
b. Provide drain tile and gravel fill
c. Backfill behind wall with material stockpiled on site.
d. Finish grade with topsoil stockpiled on site

Click to download CD set from Hodge & Assoc.